Carbon footprint data collection means pulling the quantity of every emission source (fuels, electricity, refrigerants, purchased materials) out of source documents and into one calculation file in a way that can be traced back: gas and electricity invoices, meter readings, fuel purchase and stock records, service sheets and purchasing lists. The calculation itself is a simple multiplication. The real work is finding the right quantity, in the right unit, with no gaps, and with a trail an auditor can follow. This guide covers where each piece of data sits, the unit errors we see most often, and what to do when data is missing.
It draws on the GHG Protocol Corporate Standard and Scope 3 Calculation Guidance, the European Commission's CBAM Guidance No. 3 (14 August 2026), the 2006 IPCC Guidelines and the Turkish energy regulator's (EPDK) natural gas billing rules. The examples come from Turkish manufacturing sites, so EU buyers working with Turkish suppliers will recognise the documents involved. If scope boundaries are not settled yet, start with our scope 1, 2 and 3 guide.
Where does each piece of data sit?
Start with a data inventory: for each emission source, write down the document you will use, its unit and who supplies it. The table below is typical for a manufacturing plant.
| Emission source | Document | Unit | Owner | Scope |
|---|---|---|---|---|
| Boilers, furnaces, kilns (natural gas) | Distribution company or industrial zone invoice, site meter | Sm³, kWh | Energy / accounting | 1 |
| Generators, forklifts (diesel, LPG) | Fuel purchase invoices, tank stock records | Litres, kg | Purchasing / maintenance | 1 |
| Company vehicles | Fuel card statement | Litres | Facilities | 1 |
| Air conditioning, refrigeration, fire extinguishers | Service and refill sheets | kg of gas | Maintenance / contractor | 1 |
| Process inputs (limestone, electrodes, carbonates) | Weighbridge records, lab analyses | Tonnes, % carbon | Production / quality | 1 |
| Grid electricity | Electricity invoice, main and sub-meters | kWh (active) | Energy | 2 |
| Purchased goods and services | Purchasing ledger, supplier declarations | Tonnes, currency | Purchasing | 3 |
| Freight, business travel, staff shuttles | Freight invoices, travel records, shuttle contract | t-km, km | Logistics / HR | 3 |
The same list maps onto the six ISO 14064-1 categories; see our ISO 14064 GHG inventory page for the mapping.
Natural gas invoices: gross versus net calorific value
Turkish gas invoices show consumption in both cubic metres and kilowatt-hours. EPDK's billing communiqué converts units on the basis of a gross calorific value of 9,155 kcal/m³ (1 m³ = 10.64 kWh), and distribution companies correct each period with the measured gross calorific value. The kWh on the invoice is therefore a gross figure.
The emission factors in the IPCC Guidelines and in CBAM guidance are based on net calorific value. The 56.1 t CO2/TJ default for natural gas is a net figure, and according to the IPCC the net value of natural gas is about 10% lower than the gross value. Multiplying invoice kWh directly by the factor overstates emissions.
| Calculation | Energy | Emissions |
|---|---|---|
| 1,000,000 kWh from the invoice (gross) | 3.60 TJ | 3.60 × 56.1 = 202.0 t CO2 (wrong) |
| Converted to net (≈ 10% lower) | 3.24 TJ | 3.24 × 56.1 = 181.8 t CO2 |
The gap here is about 20 tonnes, or 11%. The 10% ratio is a rule of thumb; for an exact figure use the calorific value published by the distribution company or a gas analysis, and record which value you used. You can also convert Sm³ with a net calorific value. What matters is that the activity data and the factor sit on the same basis. If you buy from a Turkish supplier and their natural gas emissions look high, this is the first thing to check.
Electricity: billing periods do not match the calendar
Electricity invoices follow meter reading dates. If the meter is read on the 12th, the January invoice mixes December and January days. For an annual inventory either ask the supplier, industrial zone or distribution company for consumption by calendar month, or split the first and last invoices pro rata by days. Write down the method and keep it the same every year.
- Active energy only: reactive energy lines on the invoice are not part of the emissions calculation.
- Main and sub-meters: the main meter is enough for a corporate footprint. If CBAM requires electricity to be split across production processes, you need sub-meters or a documented allocation key.
- On-site generation: rooftop solar or CHP output and any export to the grid are tracked on separate meters.
Example: a plant supplied from the distribution grid that uses 2,400 MWh a year applies the Turkish Ministry of Energy's 2023 consumption-point factor (0.469 t CO2e/MWh) and reports about 1,126 t CO2e in scope 2. Which factor applies when is covered in our emission factors guide; the different CBAM rule for grid power is explained in our CBAM indirect emissions article.
Liquid and solid fuels: account for stock changes
Natural gas flows continuously and is read from a meter. Diesel, fuel oil, LPG, coal and petcoke arrive in batches and sit in storage, so the amount bought in a year is not the amount burned. CBAM Guidance No. 3 (section 4.6.1.3) sets out the balance for batch-wise fuels:
Consumption = Input − Output + Stock at start − Stock at end
Example: the tank holds 4,000 litres of diesel on 1 January, 30,000 litres are bought during the year, none is sent to another site, and 6,000 litres remain at year end. Consumption is 4,000 + 30,000 − 6,000 = 28,000 litres, not the 30,000 on the invoices. Where measuring stock directly would mean unreasonable cost, the guidance allows estimates based on previous years or audited financial statements, as long as the deviation is recorded.
Fuel measured in litres is converted to mass with density and then to energy with net calorific value. Use supplier declarations or national inventory values, and store the source next to the factor. For vehicles, a fuel card statement is far more reliable than collecting receipts.
Refrigerants and process inputs
Leaks from air conditioning, cold rooms and chillers matter even in small quantities, because these gases have global warming potentials hundreds or thousands of times that of CO2. A common simple method takes the gas type and the kilograms added during the year from the contractor's refill sheets: gas added replaces gas lost. A contract clause requiring a signed sheet with gas type and kg at every refill makes the year-end trail much easier.
For process emissions (limestone, dolomite, electrodes, carbonate raw materials) data comes from weighbridge records and laboratory analyses. CBAM sets detailed rules on sampling and analysis frequency; for sector examples see our steel and aluminium and cement articles.
Scope 3: purchasing and supplier data
Most scope 3 data sits outside the plant. The GHG Protocol Scope 3 Calculation Guidance defines four methods for purchased goods and services.
| Method | Data needed | When to use |
|---|---|---|
| Supplier-specific | Supplier's product-level cradle-to-gate emissions | High-volume suppliers able to provide data |
| Hybrid | Supplier's energy and waste data plus secondary factors | Supplier can provide partial data |
| Average-data | Quantity bought (tonnes, units) × industry-average factor | Quantity known, no supplier data |
| Spend-based | Spend × monetary factor | First screening; the roughest method |
A practical route is to screen the whole purchasing ledger spend-based, find the largest items, then move those to quantity or supplier data. The guidance also notes that supplier-specific results are not automatically more accurate, so ask how the supplier's figure was calculated. EU buyers sending data requests to Turkish suppliers will get better answers if they ask for the method and factor source alongside the number.
Data quality: meters, calibration and gaps
Collecting data is not enough; you also need to show it can be trusted. CBAM Guidance No. 3 gives the most concrete criteria of any official document, and they are a sensible benchmark for corporate inventories too.
- Meter uncertainty: 1.5% or better for source streams above 500,000 t CO2 a year; below 7.5% is acceptable for those under 10,000 t.
- Whose meter: if you have no instrument of your own, the supplier's commercial meter (often under legal metrological control) or its invoices may be used.
- Calibration: instruments are calibrated at regular intervals and the records kept; a failed meter is replaced by one at least as accurate.
- Missing data: gaps are filled with conservative estimates that neither understate emissions nor overstate production. The guidance's example is an unweighed truck: use the average of similar loads in the period plus one standard deviation. The method goes into the monitoring plan.
Improving data later also leaves a mark. The GHG Protocol requires the base year to be recalculated when better activity data or emission factors change base year emissions significantly.
Data flow and controls: what auditors look at
To build a control system, Guidance No. 3 recommends mapping the data flow from the first point where data appears (a fuel invoice, a meter reading) to the final figure. Data copied by hand from a paper production log into an unprotected spreadsheet is named explicitly as a significant error risk. In practice:
- Give each emission source one owner and one source document.
- Collect data monthly; waiting for year end turns lost invoices and late documents into gaps you cannot close.
- Store the document number or file next to every figure entered.
- Have different people enter and check the data (four-eyes principle).
- Compare with the previous year and with production; if fuel per tonne of product jumps, write down why.
- Keep records: CBAM monitoring records for at least six years after the reporting period, ten years under the Turkish ETS Regulation.
Where spreadsheet-based teams typically struggle is covered in our carbon accounting Excel vs software article.
Where Carbonet fits
Carbonet is a carbon footprint and CBAM software developed by LNA Soft in Izmir, Türkiye. It is built to split data collection across departments: energy, logistics, purchasing and others each enter and see only their own data, and the number of users does not change the price. The emission factor source (IPCC, DEFRA, EPA, TÜİK) and AR5/AR6 choice are set per user, and the source and version are stored with every calculation. Fuel, electricity and process data entered for the carbon footprint flow into the CBAM calculation, so nothing is entered twice. EU importers sourcing from Türkiye can also see CBAM Turkey.
Conclusion
A good carbon inventory is the product of a good data collection routine. Handling the gross and net calorific value gap for gas, stock changes for stored fuels, billing periods for electricity and refill sheets for refrigerants keeps the result from drifting by tens of percent. When every figure has a document, an owner and a written method behind it, verification becomes much easier.
To set up your plant's data collection with us, request a demo, write to info@carbonet.com.tr or reach us on WhatsApp: +90 533 368 05 99.
Frequently asked questions
Which documents are needed for a carbon footprint?
Natural gas and electricity invoices, meter readings, fuel purchase invoices and tank stock records, fuel card statements, refrigerant service sheets, weighbridge records and lab analyses, and for scope 3 the purchasing ledger, freight invoices and supplier declarations.
Can the kWh on a gas invoice be multiplied directly by the emission factor?
No. Gas is billed on gross calorific value, while IPCC and CBAM fuel factors are based on net calorific value. For natural gas the net value is about 10% lower, so skipping the conversion overstates emissions by roughly 11%.
Is the fuel bought in a year the same as the fuel consumed?
Not for stored fuels. Consumption equals input minus output plus opening stock minus closing stock. Stock measurements and any fuel sent to other sites need to be recorded.
What should be done when data is missing?
Fill the gap with a conservative estimate that neither understates emissions nor overstates production, for example the average of similar loads in the period plus one standard deviation. Record the method in the monitoring plan or inventory procedure.
Do I have to get scope 3 data from suppliers?
No. The GHG Protocol allows supplier-specific, hybrid, average-data and spend-based methods. In practice companies screen spend first and move the largest items to quantity or supplier data.
How long should carbon inventory records be kept?
Under CBAM, monitoring records are kept for at least six years after the reporting period; installations under the Turkish ETS Regulation keep them for ten years. Keeping corporate inventory evidence at least as long helps with base year tracking and verification.