·10 min read

Emission factors: what they are and which source to use (Türkiye and CBAM)

An emission factor turns activity data into greenhouse gas emissions. How to choose between IPCC, national inventory, DEFRA and Turkish grid factors, and why scope 2 and CBAM follow different rules.

Emission factors: what they are and which source to use (Türkiye and CBAM)

An emission factor is a coefficient that converts an activity into greenhouse gas emissions: 56.1 tonnes of CO2 per terajoule of natural gas burned, for example, or 0.436–0.469 tonnes of CO2e per megawatt-hour of grid electricity consumed in Türkiye. Emissions are calculated by multiplying activity data by that factor. Which source and which year you pick can shift the result by tens of percent, and it is one of the first things a verifier checks.

This guide is based on the IPCC Guidelines, the European Commission's CBAM Guidance No. 3 (14 August 2026) and the 2023 electricity emission factor information sheets published by Türkiye's Ministry of Energy and Natural Resources on 26 December 2025. It is written for sustainability teams, EU buyers reviewing supplier data and Turkish exporters. If you need a refresher on scope boundaries first, see our scope 1, 2 and 3 emissions guide.

What is an emission factor and how is it used?

Most corporate greenhouse gas inventories are calculated, not measured. Only a minority of installations run continuous stack monitoring; most companies work from fuel invoices, meter readings and purchase records. The emission factor is the bridge that turns those quantities into emissions.

Emissions (t CO2e) = Activity data × Emission factor × Global warming potential (GWP)
  • Activity data: fuel consumed (TJ, tonnes, m³), electricity (MWh), distance travelled (km), materials purchased (tonnes).
  • Emission factor: the amount of gas per unit of activity, typically t CO2/TJ for fuels, t CO2/MWh for electricity and t CO2/t for materials.
  • GWP: converts methane (CH4), nitrous oxide (N2O) and other gases into CO2 equivalents. If the factor is already expressed in CO2e, this step is built in.

Unit mismatches cause more errors than anything else. If the factor is energy-based (t CO2/TJ), the cubic metres or tonnes on the invoice must first be converted to energy using the net calorific value. If the value on your supplier's invoice differs from the one assumed by the factor source, the result drifts.

GWP values: AR5 or AR6?

The same amount of methane gives a different CO2e figure depending on which IPCC Assessment Report you use. The gap looks small, but it matters for companies with significant refrigerant leaks, waste or agricultural emissions.

GasAR5 (100-year)AR6 (100-year)
CO211
CH4 (fossil)2829.8
N2O265273

National inventories under the Paris Agreement are reported with AR5 values. In a corporate report, what matters is that you state your choice and apply the same set to the base year and every later year. If you switch GWP sets, recalculate the base year; otherwise any "reduction" or "increase" simply reflects a change of coefficients.

The main emission factor sources

There is no single "correct" database. The right source depends on the purpose of the report, the country where the activity takes place and the quality of your own data.

SourceWhat it providesWhen it fits
IPCC 2006 Guidelines and Emission Factor Database (EFDB)International default values for fuels and processesFuel combustion and carbonate decomposition; the baseline where no national value exists
Türkiye's National GHG Inventory (TurkStat)Country-specific fuel and sector factorsActivities in Türkiye; more representative than IPCC defaults
Ministry of Energy information sheetsElectricity generation and consumption-point factorsGrid electricity consumed in Türkiye (scope 2)
UK DESNZ conversion factors (formerly DEFRA)Broad list covering transport, materials, waste, well-to-tankScope 3 categories; UK electricity, not Turkish electricity
US EPA Emission Factors HubUS-focused fuel, electricity and transport valuesActivities in the US, some scope 3 categories
Supplier data and laboratory analysisValues specific to your fuel or materialMajor emission sources; the highest accuracy

The DESNZ 2026 set was published on 11 June 2026 and is designed for UK activities. It is widely used for items such as freight and materials, but applying the UK grid electricity factor to a plant in Türkiye is a mistake.

Which electricity emission factor applies in Türkiye?

This is the error we see most often in supplier data. The Ministry publishes two separate information sheets, and they serve different purposes.

Factor (2023)ValuePurpose
National average electricity generation0.434 t CO2e/MWhAverage of generation
Consumption point, transmission-connected0.436 t CO2e/MWhScope 2 for sites supplied at high voltage
Consumption point, distribution-connected0.469 t CO2e/MWhScope 2 for sites supplied by a distribution company
Combined margin (solar and wind)0.6242 t CO2/MWhAvoided emissions of renewable energy projects
Operating margin0.7134 t CO2/MWhInput to the combined margin

On its grid emission factor page, the Ministry states plainly that the combined margin value does not mean that 1 MWh of solar power emits 0.6242 tonnes of CO2; it represents the emissions a new solar or wind plant would avoid. The Ministry also notes that this sheet contains no factor for organisations consuming electricity from the grid. For corporate scope 2, the correct sheet is the one on electricity generation and consumption-point factors, and it matters whether the site is connected to the transmission or the distribution network.

The second issue is timing. The 2023 values were published in December 2025; the 2022 consumption-point factors were 0.442 and 0.474. When preparing a 2025 inventory, state that you used the latest published year and how you will handle the next release.

If you buy renewable energy certificates (Turkish YEK-G or I-REC) or a green tariff, the GHG Protocol Scope 2 Guidance asks for two figures: a location-based result using the grid average and a market-based result reflecting your contracts. Certificates only affect the market-based figure.

Example: the cost of the wrong factor

Take a hypothetical distribution-connected site consuming 5,000 MWh of electricity a year:

  • With the correct factor (0.469): 2,345 t CO2e
  • With the combined margin (0.6242): 3,121 t CO2e, or 33% too high
  • With the operating margin (0.7134): 3,567 t CO2e, or 52% too high

If the same site burns 30 TJ of natural gas, the IPCC default (56.1 t CO2/TJ) adds 1,683 t CO2. In other words, the wrong electricity factor can inflate the total footprint by roughly half of the natural gas line.

How are emission factors chosen under CBAM?

The rules for calculating embedded emissions of CBAM goods are stricter than for corporate reporting. Guidance No. 3 splits fixed values into two groups and expects the more accurate group to be used first:

  • Type I standard values: the standard factors in Annex II, Section G of Methodology Regulation (EU) 2025/2547 (taken from the IPCC 2006 Guidelines, e.g. natural gas 56.1, gas/diesel oil 74.1, lignite 101.0 t CO2/TJ), the latest IPCC Guidelines, and past laboratory analyses no older than five years.
  • Type II standard values: factors from the installation country's latest national inventory submitted to the UNFCCC, more disaggregated values published by public bodies, supplier-guaranteed values where the carbon content has a 95% confidence interval of no more than 1%, and laboratory analyses no older than two years.
  • Analysis: for major source streams, analysis by an accredited laboratory is best practice.

The values you use are written into the monitoring plan. Where a value comes from a source that changes every year, the plan names the authoritative source and the update procedure rather than the number itself.

Electricity works differently. For cement, fertilisers and sintered ore, where indirect emissions count, grid electricity is calculated with the country average published by the Commission in Annex II of Default Values Regulation (EU) 2025/2621, based on International Energy Agency data. The Turkish Ministry's consumption-point factor is the right source for corporate reporting, but it is not automatically valid for CBAM. An actual factor may only be used where a direct technical link to the generator or a power purchase agreement (PPA) with physical delivery is documented; purely financial "virtual PPAs" do not qualify, and green energy certificates are not among the conditions listed in Guidance No. 3. For iron and steel, aluminium and hydrogen, only direct emissions are included. The evidence list and Türkiye examples are in our CBAM indirect emissions guide. For more detail, see our CBAM report guide and our CBAM embedded emissions calculation page.

Six questions to ask before choosing a source

  1. What is the report for? An ISO 14064-1 inventory, a CBAM declaration and Turkish ETS monitoring follow different rules. You may need two separate factor sets for the same site.
  2. Where does the activity take place? Electricity and fuel factors are country-specific. Do not apply UK or US values to activities in Türkiye.
  3. Which year is the value from? Record the gap between factor year and reporting year, and your update rule.
  4. Are the units consistent? Does the invoice unit match the factor unit, and where does the calorific value come from?
  5. Which sources are material? For the two or three sources that drive most emissions, move from defaults to supplier data or analysis; defaults are fine for small sources.
  6. Is there an audit trail? A verifier wants to see the source name, version and table or page number behind every figure.

That last point is the weak spot of spreadsheet-based inventories. Once a factor is typed into a cell, its source and year fade from view. We covered this in detail in carbon accounting in Excel vs software.

How Carbonet manages emission factors

Carbonet is carbon footprint and CBAM software developed by LNA Soft in Izmir, Türkiye. Its factor library ships with IPCC, DEFRA, EPA and TurkStat sources, and the IPCC Assessment Report (AR5 or AR6) and factor source can be selected per user. The source and version of each factor are stored with every calculation, so the verifier can see where each figure came from. Base-year and later-year factors can be moved to the current database with a single click. For inventories structured around the six ISO 14064-1 categories, see our ISO 14064 GHG inventory software page.

Conclusion

The emission factor is the smallest part of a carbon footprint, and one of the most influential. The right source is chosen for the purpose, the country, the year and the quality of your data, and the reasoning is recorded. For sites in Türkiye, the critical distinction is this: use the Ministry's consumption-point factor for corporate scope 2, and the Commission's default grid factor for CBAM.

To see a factor set applied to your own data, request a demo or write to info@carbonet.com.tr or on WhatsApp (+90 533 368 05 99).

Sources: IPCC 2006 Guidelines for National Greenhouse Gas Inventories; IPCC AR5 and AR6 global warming potentials; European Commission CBAM Guidance No. 3 (14 August 2026) and its Annex D standard values; Implementing Regulations (EU) 2025/2547 and 2025/2621; Türkiye Ministry of Energy and Natural Resources 2023 information sheets on the national grid emission factor and on electricity generation and consumption-point emission factors (26 December 2025); GHG Protocol Scope 2 Guidance; GOV.UK Greenhouse gas reporting: conversion factors 2026. The example site is hypothetical. This article is for general information only.

Frequently asked questions

What is an emission factor?

It is a coefficient showing the greenhouse gas emitted per unit of activity. Activity data such as fuel, electricity or materials is multiplied by the factor, and by the global warming potential where needed, to give tonnes of CO2 equivalent.

What is the grid emission factor for Türkiye?

According to the Ministry of Energy's 2023 information sheet, the consumption-point factor is 0.436 t CO2e/MWh for transmission-connected sites and 0.469 t CO2e/MWh for distribution-connected sites. These values are used for corporate scope 2.

Can the 0.6242 t CO2/MWh factor be used for scope 2 in Türkiye?

No. It is the 2023 combined margin factor and represents emissions avoided by a new solar or wind plant. The Ministry states that this sheet contains no factor for organisations consuming electricity from the grid.

Can DEFRA conversion factors be used outside the UK?

They are widely used for some scope 3 categories such as freight, materials and waste. However, the DESNZ (DEFRA) set is designed for UK activities, and the UK grid electricity factor should not be applied to consumption in other countries.

Does CBAM accept national grid emission factors?

Not automatically. For grid electricity, CBAM uses the country factor published by the Commission in Annex II of Regulation (EU) 2025/2621, based on IEA data. An actual factor requires a documented direct technical link or a PPA with physical delivery.

Should I use AR5 or AR6 GWP values?

National inventories under the Paris Agreement use AR5. In corporate reporting, state which set you chose and apply it consistently to all years including the base year; if you switch sets, recalculate the base year.